A level of anesthesia where a patient is in a drug induced state and responds normally to verbal commands, although coordination may be impaired, is_______________________.
Area alarms provide________and_________surveillance of category_____and______systems.
A warning system (alarm), located at a medical air compressor control panel to indicate when the medical air dew point is high, is known as a(n)__________alarm.
A gas used for operating medical-surgical tools or removing excess moisture from instruments is a(n)___________________,
Facility systems in which failure of the equipment or system is likely to cause major injury or death of patients is a___________system.
An oxygen-enriched atmosphere contains above________% of oxygen by volume.
The individual responsible for enforcing the NFPA 99 code is called:
The air quality tests for the medical air compressor system shall be conducted after the system has been operating under a simulated load for _____ hours with the source valve ____________.
A standard is a document which contains only mandatory provisions using the word “shall” to indicate requirements and:
The purpose of the NFPA 99 code is to provide minimum requirements for:
Branch or lateral lines are those sections of the piping system that serve:
A patient care room is any room of a health care facility wherein patients are intended to be _____________ or_____________.
A test for dew point shall be conducted at the ____________ of the medical air compressor and the limit value of the pressure dew point shall be_______.
Final line pressure regulators shall have ____________________ located downstream of the isolating valves for the regulators.
In central supply systems using cylinders containing either gas or liquid, each header shall contain ____________ and_____________.
Systems shall be deemed breached at the point of pipeline intrusion by physical separation or by system component____________, replacement, or______________.
The medical air intake shall be located a minimum of _____ ft. from any door, window, or other opening in the building, and _____ ft. from plumbing vents.
___________________ and __________________ shall be of brass, bronze, or stainless steel construction.
Medical air compressor intake piping shall be permitted to be constructed of all the listed materials except:
Final line pressure regulators for bulk oxygen systems shall be of a ___________ design.
If a central supply system supplies separate piped distribution networks operating at different pressures, each network shall have all of the following except_______________.
A reserve header on a manifold for cryogenic liquid containers shall have a minimum of _____________________ connections.
Manifolds for gas cylinders without reserve supply shall have a(n) _________ signal indicating operating status, and shall activate an audible indicator at all __________ alarms.
Oxygen cylinders in use and in storage shall be prevented from reaching temperatures in excess of______.
Interconnecting hose (pigtails) intended to handle ______________ at gauge pressure greater than_____PSI shall contain no polymeric materials.
The valve located on the facility side of the source valve, and outside of the source room, where the main line first enters the building is a _________ line valve.
_________ valves shall be placed such that a wall intervenes between the valve and the outlets/inlets that it controls.
Optional _______ valves shall be permitted to be installed to isolate piping for servicing of individual rooms or areas.
Master alarm panels shall communicate ___________ to the alarm initiating devices that they monitor.
In a WAGD system, the concentration of _____________ and _____________ shall be maintained below 23.6%.
The piping in a Category 3 gas system which may not be installed in a floor slab is ________________.
____________________________ shall be permitted to be installed in enclosures containing only instrument air compressors.
Area alarm panels for critical care areas shall have the sensors installed on the ________________ side of the individual zone valve box assemblies.
Verification tests on medical gas systems shall be performed only after all __________ tests have been completed.
A(n) ________ valve shall be located immediately outside each vital life support area, critical care area, and anesthetizing location.
The quality of instrument air shall be filtered to _____ micron and dry to a dew point of______, and be compliant with_________.
Manifolds for cryogenic liquid containers shall have a means to discharge gas produced by the evaporation of the cryogenic liquid in the system _________ of the ___________ regulator assembly.
Bulk supply systems for oxygen with a total capacity connected and in storage of _______ cubic feet or more shall comply with__________.
Indoor central supply system locations shall have interior construction of a minimum ______ fire rating.
Nitrogen and instrument air systems have pipe labels located at intervals of not more than _____ ft., and operate at a standard gauge pressure of _________.
Flexible connectors shall be suitable for an operating service pressure at ______ PSI, and able to withstand temperatures of _______.
An emergency oxygen supply connection shall have a minimum of ______ of clearance around the EOSC for connection of a temporary source.
The correct uses of medical air are____________________________________________________.
Oil free reciprocating medical air compressors have a high temp sensor that activates a(n) ________ alarm indicator, and shall be monitored for gaseous hydrocarbons on a(n) _________ basis.
Instrument air systems shall have a dew point alarm that activates a local alarm, and alarms at all master panels when the dew point exceeds______.
If a medical vacuum system is serving a teaching laboratory, the piping for the laboratory vacuum lines shall connect directly to__________________.
All valves shall be labeled for ____________ and ______________.
Manufactured assemblies which employ flexible hose shall use hose with a minimum burst pressure of _______.
Zone valves for ______________ and ______________ areas shall be permitted to be secured with the approval of the AHJ.
Each station inlet shall have a __________ valve, and shall be permitted to have a __________ valve (optional).
Factory installed copper inlet tubes on station inlets shall not be less than______NPS size, with minimum ______ inside diameter.
A bulk oxygen system which is located outside of, and remote from the building being served, shall have __________ set(s) of alarm wires run between the building junction box and the source system.
Medical gas equipment which must be tested on a regular preventative maintenance schedule as determined by the facility maintenance staff shall include__________________________.
Oxygen and medical air outlets serving critical care areas shall allow a flow rate of____SCFM for _______ seconds.
Inspection schedules for medical gas equipment and procedures shall be established through ____________________ and developed with _____________________.
The type of equipment which uses flexible connectors internally, and which must be tested for leaks every 18 months is______________.
Medical gas equipment which must be reviewed annually for sufficient capacity are______________.
Medical gas equipment which must be calibrated shall include_________________.
Persons which maintain medical gas systems shall have qualification training demonstrated by which of the following ASSE credentials?
The alarm point for instrument air dew point monitors is _____ degrees, and the final line filters shall filter to ______ micron.
Audible and visual alarm indicators for area alarm panels shall be tested ____________ per NFPA 99.
Medical gas outlets which deliver 5.0 SCFM @ 160-185 PSI are known as ________ outlets.
The total pressure in a system, with reference to zero pressure is:
Zone valves shall be so arranged that shutting off the supply of gas to any one ______________ room will not affect the others.
Bulk cryogenic liquid source systems shall be inspected in accordance with:
The ASSE 6040 credentialed medical gas maintenance person shall, as part of the maintenance program, inspect valves for proper ____________________.