The maximum test pressure on an Amico medical gas outlet without the latch valve installed (rough-in only) is _____Â PSI.
To rebuild/repair an Ohmeda compatible Amico latch valve assembly, you would need to order repair kit ______________ .
If the latch valve assembly is installed on an Amico oxygen outlet, the maximum test pressure is_____ PSI.
The part number for a Beacon Medaes Diamond 3 oxygen outlet finish assembly is _______________ .
If a Beacon Medaes Diamond 3 outlet is leaking with a quick connect adapter in place, the most
likely cause could be __________________ .
Amico DISS latch valve assemblies do not have o-ring seals on ________, _________, and
_________ medical gases.
Amico medical gas outlets should be inspected periodically, or at least ____________ .
Beacon Medaes outlets in high use areas should be inspected at least _________, and more frequently if outlets are used daily.
On Beacon Medaes Gemini/Diamond 3 outlets front bodies which are being rebuilt, new _________ must be used when reassembling the front body assemblies.
Beacon Medaes outlets elastomer seals may be lubricated sparingly with _____________ .
The minimum width on Becker KVT 2.000 series pumps valves prior to replacement is _________.
Bearings on Becker VTLF 200 pumps should be greased every _______ hours.
When a Becker DTLF pump lacks sufficient vacuum, a common possible cause could be ____________.
Intake filters on Becker VTLF 200 pumps should be checked and cleaned at least every _______.
Becker dry vane pump vane life is mostly dependant upon ___________________________.
Discharge filters on Becker KVT 3.140 pumps should be checked (and replaced if necessary) every ___________.
Vanes on a Becker VTLF400 pump should be checked for minimum width every ______________.
If carbon vanes on Becker DTLF pumps become stuck, they should be _______________.
Intake filters on Becker VT 4.10 pumps should be blown out _______.
The vacuum relief valve on Becker vacuum pumps must be periodically adjusted. When making this adjustment, a vacuum gauge should be placed on the inlet port, and the pump should be operated under no load for approximately ___________.
Busch MM vacuum pump gear oil should be changed every _____ hours or ____ years, using Busch approved gear oils, operating at standard conditions.
The inlet air filter on Busch MM vacuum pumps should be inspected _______ .
Rietschle C-VLR vacuum pumps should be operated at a maximum ambient temperature of ____ degrees centigrade.
The oil in a Rietschle C-VLR vacuum pump should be changed at _____ hours.
The coupling sprocket on a Rietschle C-VLR vacuum pump should be checked at least _______.
The correct gear oil level in a Busch MM vacuum pump should be ______________________________________ .
If a Busch MM vacuum pump drive motor is running and the pump is not running, the most probable cause is __________________________________ .
The Rietschle C-VLR vacuum pumps which have grease lubricated bearings on the B side are the __________ .
If a suction filter is installed on a Busch MM vacuum pump, it should filter foreign solid particles down to ____ microns or less.
On a Rietschle C-VLR vacuum pump, the allowable power supply voltage deviation from the motor data plate is _____ percent (without derating).
Busch R5 vacuum pump’s oil should be changed (after the first initial 100 hours of operation) every 3 to 4 months, or _____ to _____ hours, if not exposed to high heat operating conditions.
If a Busch R5 vacuum pump is running very noisily, one possible cause is _____________________ .